AC Not Cooling After Power Surge: Reset and Repair Guide

Power surges don’t announce themselves. One moment the house hums along under summer load, the next your thermostat reads 76 while the vents blow room-temperature air. If your AC stopped cooling right after the lights flickered or a breaker tripped, you’re not imagining the connection. Surge events, even short ones, can scramble controls, trip protective devices, and occasionally damage components. The good news is many post-surge cooling failures can be fixed with a careful reset and a few targeted checks, no special tools required. The rest require measured diagnostics so you don’t damage an already stressed system.
I’ve walked homeowners through dozens of these calls on the phone and in driveways. The pattern repeats often enough that a methodical approach pays off. What follows is a practical guide to getting your system cooling again, understanding what might have failed, and deciding when to call a pro.
Why surges knock AC systems off balance
A split central AC system relies on coordinated low-voltage control and high-voltage power. The thermostat energizes a circuit that signals the outdoor condenser contactor and the indoor blower relay. Surge energy and brownouts interfere with both sides.
Short, sharp spikes can pit contactor faces, scramble thermostats, and pop low-voltage fuses on the furnace or air handler’s control board. Longer undervoltage dips can stall compressor motors, forcing thermal overloads to open. Even when nothing “burns out,” safety devices do what they’re designed to do: they interrupt operation to prevent damage. That is why a reset often restores service.
On modern systems with inverter-driven compressors, variable-speed blowers, and integrated boards, sensitivity increases. Those electronics ride on delicate logic power paths. Temporary distortions can trigger lockouts that remain until reliable hvac repair services power is fully removed for a set period.
The safe reset sequence that solves half of surge problems
If I could pin a single page to every electrical panel, it would be the post-surge AC reset. It avoids the most common mistake, which is rapid-fire breaker flipping while the system is mid-protective cycle. Mechanical and electronic protections need time to discharge and clear.
Here is the brief, effective sequence I teach and use.
- Set the thermostat to Off. If it has a Cool/Heat/Auto mode selector, choose Off. On heat pumps, also set the fan to Auto rather than On.
- Turn off power to the indoor unit. This is usually a light switch on or near the furnace/air handler, or a breaker labeled Furnace, Air Handler, or Air Conditioner in the main panel.
- Turn off power to the outdoor unit. Use the disconnect near the condenser, or the breaker labeled AC Condenser or Heat Pump.
- Wait at least 5 minutes, ideally 10. This allows compressor pressures to equalize and electronic boards to fully de-energize. Skip this and you risk hard starting a hot compressor.
- Restore power: indoor unit first, then outdoor unit. After both have power, set the thermostat to Cool and drop the setpoint well below room temperature. Give the system 5 to 10 minutes to stabilize airflow and refrigeration.
If the outdoor fan and compressor start and deliver cold air, you likely had a control lockout or tripped thermal overload. Let it run for a full cycle and watch for abnormal sounds. If nothing happens, or only the blower runs with no cold air, continue below.
Thermostat sanity checks after a surge
Thermostats are more fragile than they look. Many models use tiny switching components and rely on stable 24-volt power from the indoor unit. A surge can corrupt their logic or confuse their time delays. A few quick checks rule out the simple stuff.
Remove the thermostat face and look for any reset or battery. If it uses batteries, replace them, not because they suddenly died, but because surge events can expose a marginal cell that then causes random reboots. Confirm the thermostat displays the correct mode and that “Cool” or a snowflake icon appears. If you recently changed the mode to Heat and now the furnace not heating scenario appears, remember that surges can also flip system settings on smart thermostats. Double-check that your cooling type is still set correctly in any installer menu, especially on heat pumps where O/B reversing valve settings matter.
If the thermostat shows a delay message, let it count down. Many models enforce a 2 to 5 minute anti-short-cycle delay. Cyclone the breakers during that period and the timer restarts, which looks like nothing works.
Finally, for older mechanical thermostats or simple digital units, gently lower the setpoint 8 to 10 degrees below room temperature to guarantee a clear call for cooling. You want to force the system to try, not hover on the edge of a satisfied setpoint.
The low-voltage fuse that often dies quietly
Inside most furnaces or air handlers sits a 3 to 5 amp blade fuse on the control board. It protects the 24-volt transformer and downstream controls from short circuits. Surges can cause tiny arcs at contact points that briefly short the low-voltage circuit and pop the fuse. The symptom is a dead thermostat, a thermostat that lights but won’t call anything, or a blower that runs on a fixed speed but no outdoor response when average hvac system lifespan calling for cooling.
Kill power at the switch or breaker before opening panels. Inspect the board for an automotive-style fuse labeled 3A, 5A, or similar. If it’s blackened or propane heater not working the internal link is open, replace it with the exact same amperage. Keep a couple spares on hand. If it blows again immediately, suspect a shorted contactor coil outside, a pinched thermostat wire, or water in the condensate safety circuit. This is where a multimeter and some experience pay off. Without them, the quickest clue is to disconnect the two small low-voltage wires at the outdoor unit’s contactor. Replace the fuse, power up, and call for cooling. If the fuse holds until you reconnect the outdoor wires, the fault is likely in the condenser’s low-voltage path.
Breakers that look fine but aren’t
Surge events can trip breakers. Some breakers only partially trip and look normal. A true reset requires flipping firmly to Off, then back to On. Check both the indoor breaker and the outdoor breaker. If either one trips again right away, something is shorted, and powering it repeatedly risks more damage.
At the outdoor disconnect, pull the handle or open the fused block and check for burnt smells or melted plastic. Fused disconnects add a layer of protection, and one or both fuses can blow cleanly during a surge. You can test continuity across those fuses with a multimeter. If you don’t have one, replace both fuses with the same rating and type. Never upsize. The fuse is supposed to be weaker than the compressor windings.
Compressor overloads and the patience factor
Compressors are the workhorses, and they hate unstable power. A stalled compressor draws locked-rotor amps until its internal thermal protector opens. After a surge, I’ve seen plenty of units that hum briefly, then go silent, then stubbornly refuse to start for 30 to 60 minutes while the overload cools and resets. That is normal behavior of the protector doing its job.
If you hear the outdoor fan spinning but no deeper rumble from the compressor, place a hand on the copper lines after a few minutes. The larger insulated suction line should turn cool to cold, and the small liquid line should feel warm. If both stay ambient and the compressor is quiet, it’s not running. If you hear a periodic click followed by silence, the compressor might be attempting and failing to start. Don’t keep cycling power. Give it a full hour powered down. If it still refuses, a start capacitor or potential relay may have failed during the surge.
On single-stage systems, a failed capacitor heating and cooling repair companies is the most common single component failure I find after a storm. Capacitors bulge on top, leak oil, or measure out of spec. Replacing one is straightforward for a trained technician and carries a shock hazard if you don’t know how to safely discharge it. If you’re not comfortable, stop here and call.
When the indoor unit runs but air is warm
If the blower motor hums along and vents deliver steady but lukewarm air, the outdoor unit is either not running or not producing refrigeration. After a surge, I check the outdoor contactor first. It is the loud “click” you normally hear when cooling starts. No click usually means the 24-volt signal is not arriving or the contactor coil is open. Verify low voltage across the coil when the thermostat calls for cooling. If the signal is present and the contactor doesn’t pull in, the coil is likely toast.
If the contactor pulls in and the fan spins, but the compressor stays silent, circle back to capacitors and overloads. Some systems use a dual-run capacitor that serves both the fan and compressor. The fan portion can be fine while the compressor portion fails. A multimeter that measures capacitance and a wiring diagram taped inside the service panel make short work of that diagnosis.
Less common after surges but still possible is a misbehaving condenser fan motor. If the fan lags or cannot keep up, head pressure climbs and the high-pressure switch opens. The unit rests until it cools. Look for a fan that starts late, turns slowly, or gets hot to the touch. Don’t stick a stick or finger in the fan cage. If a tiny nudge gets it going, that motor or its capacitor is failing.
Drain safeties that save ceilings, then stop cooling
This one catches people. Many air handlers include a float switch in the condensate drain pan. A surge doesn’t clog drains, but brownouts can stall blowers while the evaporator coil is cold, producing excessive condensate that overwhelms a marginal drain. The float switch opens the low-voltage cooling circuit to prevent overflow. After the event, the switch may stay tripped if water still sits in the pan.
Remove the secondary drain pan water and clear the primary drain trap. Blow it with nitrogen or a wet-dry vac. Reset the float switch if it has a manual reset. The clue is a thermostat that seems normal but the outdoor unit refuses to start, and the indoor blower either runs on fan-only or not at all depending on the wiring.
What surges do to heat pumps in cooling and heating modes
Heat pumps take everything above and add a reversing valve that shifts refrigerant flow. Surges can swap the valve if the control settings flip or if the thermostat loses its O/B orientation. The symptom is bizarre: the system runs but it heats when it should cool. I’ve seen homeowners call with AC not cooling when the registers were actually warming the house. On the next cold snap, the same home reports furnace not heating or heater not working because the reversing logic stayed wrong.
If you have a heat pump and your system suddenly behaves backward after a storm, check the thermostat installer setting for reversing valve energized in cooling (O) versus heating (B). Also ensure the wire labeled O/B at the indoor board and thermostat is not loose. It takes five minutes to confirm and saves a service call.
Smart thermostats and power quality quirks
Wi‑Fi thermostats ride the knife edge of low-power electronics. They reboot during sags and can get stuck in firmware limbo when power flickers. After any surge, check for firmware prompts or mismatched equipment settings. If cooling calls do not activate the outdoor unit, try a hard reset: remove the thermostat face, wait 30 seconds, then re-seat it. If the problem persists, temporarily bypass the thermostat to confirm the equipment. With power off, jumper R to Y and R to G at the furnace control board, then restore power. If the outdoor unit and indoor blower start and cooling returns, the thermostat or its sub-base is the culprit. Remove the jumper and power down before reconnecting normally.
Judging risk to compressor health
Repeated hard starts and high head pressure events shorten compressor life. Surges can weaken start windings and erode the hvac system lifespan if issues go unchecked. A single clean reset is fine. Rapidly cycling power or forcing repeated start attempts is not. If you hear loud buzzing, clicking, or see lights dim when the outdoor unit tries to start, stop and have a technician measure inrush current and evaluate the start circuit. An inexpensive hard-start kit can help an aging compressor, but installing one to mask a deeper problem rarely ends well. I view them as crutches for compressors in the last third of their service life.
When coils freeze after the power returns
It sounds unrelated, but post-surge calls often include frozen indoor coils. The chain goes like this: power comes back, the outdoor unit recovers, but the blower configuration has changed because the thermostat lost its CFM profile or the ECM blower board reset to a default low speed. Reduced airflow on a humid day drops evaporator temperature below freezing. Ten minutes later, airflow fades to a whisper and the vents feel warm. If you suspect icing, shut the system off and run the fan only for an hour to thaw the coil. Then verify blower speeds in cooling mode and check the filter. A storm day plus a dirty filter is a common two-hit combination.
Costs and when to call a technician
If the reset restores cooling and everything sounds normal, let the system run and keep an eye on it. If you needed to replace a low-voltage fuse, consider that a warning shot. Two fuses in a week means there is a real short that needs tracing. If you find a bulged capacitor or burnt contactor, those parts are in the modest range for most brands. Expect $150 to $350 per part installed in many markets, more on variable-speed or proprietary components.
Main board replacements on air handlers sit in the $300 to $900 range depending on model and availability. Outdoor inverter boards can exceed that. Compressor failures are the big-ticket items, often $1,500 to $3,500 installed, which is the decision point for repair versus replace based on system age and refrigerant type.
Age matters. If your system runs R‑22 and is over 12 to 15 years old, a surge-induced repair is a nudge to consider replacement within a season or two. That plays into the broader hvac system lifespan conversation. Conventional split systems typically last 12 to 18 years when maintained, heat pumps 10 to 16 depending on climate, variable-speed premium gear a bit less predictable due to electronics. Lightning-prone regions and frequent grid volatility shave years off those averages unless you protect the equipment.
Surge protection worth installing
Just as you use a protector on a computer, a whole-home surge protector at the main panel helps flatten spikes hitting your HVAC. Many manufacturers also offer unit-specific surge devices for condensers and air handlers. They are not magic shields, but they absorb the small to medium hits that account for most post-storm nuisance failures. Installation runs a few hundred dollars and typically pays for itself if it prevents one board or thermostat replacement. Ask for a protector rated to clamp at a low enough voltage to matter and with replaceable modules or clear status indicators.
For sensitive variable-speed systems, line voltage stabilization and clean grounds are critical. Have a technician confirm that the outdoor unit has a solid equipment ground, the disconnect is tight, and the service voltage inside the unit sits within the nameplate range under load.
Off-season heat checks after a summer surge
If a storm strikes in August and you only notice cooling issues, remember the same event might have weakened heating controls. When fall arrives, test the heat early. It is easier to schedule help in October than during the first freeze. If you find heater not working symptoms or a furnace not heating cleanly, trace back to boards, flame sensors, and inducer motors that may have logged a rough event during the summer surge. Mixed-mode systems share control power, so a surge that popped the cooling fuse may also have stressed ignition components that only show up months later.
What not to do, even if you’re handy
Do not upsize fuses or breakers. The protective device should sacrifice itself, not train the weakest link to be your compressor windings. Do not bypass safeties, especially float switches and high-pressure cutouts. Do not spray contact cleaner into a powered contactor. And avoid repeated manual contactor pressing to force a start. You can weld contacts closed and create a stuck-on condition.
Finally, resist the urge to reset every 30 seconds. Let systems fully de-energize for a few minutes between attempts. That single habit prevents a cascade of trouble that starts with a routine lockout and ends with a seized compressor.
A careful sequence for long-term reliability
A power surge isn’t just an inconvenience. It is a stress test. Your system’s response reveals weak spots, some that you can tighten up with better drainage, fresh capacitors, and surge protection. Others point to end-of-life considerations, especially in equipment approaching two decades old or running legacy refrigerants. Start with the safe reset and the simple verifications. Watch and listen to the outdoor unit. Confirm the thermostat isn’t confused by a brief electrical sneeze. If the steps above don’t restore steady cooling, press pause and call a technician with a clear description: “AC not cooling after a power surge, outdoor fan runs, compressor silent” is the kind of detail that gets the right parts on the truck and shortens the repair.
The next storm will arrive on its own schedule. A few hours invested now, including a surge protector and a sanity check on drain safeties and wiring, will stack the odds in your favor when the lights flicker again.